Maximum overall length of straight pipe.
Stove pipe installation guide.
See diagram c above for other methods please refer to nfpa 211.
You must use an approved method.
Guide to stove installation read more.
3 m 10 ft.
Every stove is different check in your owner s manual or on the tag on the back of your wood stove.
I hope this guide will help with your wood burning stove installation and that you may enjoy the warmth and memories it will create.
In the us however nfpa 211 requires at least 36 inches of clearance from combustible materials to the side or rear of a wood stove unless something less is specified in the owner s manual or there is an engineered shield on the walls.
Higher elevations or the use of an elbow or a tee will require approximately 30 to 60 more height to provide for an adequate draft.
Cvs installation instructions cvs installation instructions pdf 1 17mb cvs française instructions d installation pdf 1 17mb directvent pro installation instructions directvent pro instructions pdf 2 3mb directvent pro française instructions d installation pdf 1 8mb directvent pro horizontal termination supplement pdf 1mb directvent pro vertical wind.
Minimum chimney height at sea level of a straight or vertical chimney is 10 feet to 15 feet above the appliance outlet.
Download our chimney pipe installation guide now.
Remember unprotected single or double wall stove pipe should not pass through a combustible wall or ceiling to connect to the chimney.
Install the slip connector or telescoping section last.
A timber mantel is a common design feature but it must be sufficiently away from the stove pipe nb it is possible to use fake timber beams that are really convincing see our installation section.
For the exact rules in your area check with a local wood heat retailer chimney sweep or building inspector.
Through kits available always follow the specific manufacturers installation instructions.
Then connect it to the wall thimble.
The crimped end stub of the stove pipe adapter is intended to fit inside of the flue pipe from a solid fuel appliance thus preventing condensate drips at the chimney connection.
Installation of the stove pipe is the same as for vertical installation.
After trimming your pipe use black furnace cement to seal between each piece and three sheet metal screws at each joint.
Then attach the pipe to the stove and chimney pipe making sure it is rigid and tight.
Install inter connecting flue pipe following the appliance manufacturer s installation instructions and appropriate building.
The stove pipe must also meet minimum distances to combustible materials.
Last fasten each section of stovepipe with self tapping screws.
A wood stove is such a treat as not only does it provide heat but you can cook on it too and create many cherished family memories around it during the deepest darkest winter times.